Place of Origin : CHINA
Brand Name : HNC
Certification : CE 3C
Model Number : HV1000-IM
MOQ : 1 pc
Payment Terms : T/T, L/C,
AC drives for injection machine
HV1000 Specifications
Item | Description | ||
---|---|---|---|
Input | Rated voltage;Frequency | HV1000-4T-xxxxx:380V~440V;50Hz/60Hz HV1000-2Sxxxxx:200V~240V;50Hz/60Hz | |
Permissible fluctuation range | Continuous fluctuation range≤±10%,Short time fluctuation range≤-15%~+10%; Voltage unbalance range≤3%;Frequency≤5% | ||
Output | Rated voltage | HV1000-4T-xxxxx:0~380V/440V HV1000-2Sxxxxx:0~200V/240V | |
Frequency | 0Hz~650Hz | ||
Over load ability | G type:150%rated current for 1 minute,180%rated current for 3s/1s(380V/220V series),200% rated current for 0.5s; P type:120% rated current for 1 minute | ||
Control functions | Modulation mode | Flux vector PWM modulation | |
Speed range | 1:100 | ||
Starting torque | 180% rated torque at 0.5Hz | ||
Accuracy of speed at steady state | ≤±0.5% rated synchronous speed | ||
Torque boost | Auto torque boost,Manual torque boost | ||
Acc/Dec curve | Linear,S curve;4 Acc/Dec time; Unit(minute/second),60hours at most | ||
Jog | Jog frequency: 0.10-60.00Hz: Acc/Dec time: 0.1-60.0s. Jog interval adjustable | ||
Multi-speed operation | Seven sections of frequency. Able to achieve through the built-in PLC or terminals. | ||
Closed-loop control | Analog closed-loop,speed closed-loop control | ||
Auto energy saving operation | Voltage output is optimized automatically according to the load condition to perform energy-saving operation. | ||
Auto voltage regulation | Constant output voltage even if electric network voltage fluctuates | ||
Auto current limiting | Operating current is limited automatically to avoid frequent tripping of the inverter | ||
Auto carrier-wave regulation | Adjust the carrier frequency automatically according to the load characteristics; | ||
Customized and operating functions | Traverse for textile motor | Traverse control, central traverse adjustable | |
Set length control | When reaching set length, the inverter will stop | ||
Droop control | When many inverters control single load | ||
Tone selection | Set the tone of the motor when it is running | ||
Immunity to transient power failure | The inverter gives output even if power failure occurs | ||
Channel binding | Command channel can bind with frequency. Setting channel and switched synchonizingly | ||
Methods of inputting commands | Via keypad panel,terminals and serial port | ||
Methods of setting up frequency | Digital setting,VCI,CCI,pulse setting,serial port | ||
Auxiliary frequency | Flexible auxiliary frequency tuning,frequency synthesis | ||
Pulse output terminal | 0~50kHz pulse signal output . Signals can be reference frequency and output frequency | ||
Analog output terminals | 2 analog outputs of 0/4~20mA and 0~10V(selectable). Be able to output signals like reference frequency and output frequency. | ||
Control panel | LED keypad | Able to show many parameters, such as: frequency setting, output frequency, output voltage, etc. | |
Keypad lock | Total lock or partially lock, in order to avoid misoperation | ||
Protection function | Phase loss failure, Over/Under current, Over/Under voltage protection, Overheat and overload protection | ||
Environment | Operating environment | In-door, | |
Altitude | Less than 1000m | ||
Ambient temperature | -10℃~+40℃,derating is required from 40~50℃; Increase every 1 above 40℃, derating 2%, highest temperature allowed: 50℃ | ||
Humidity | Less than 95% RH,no condensing | ||
Vibration | Less than5.9m/s2(0.6g) | ||
Storage temperature | -40℃~+70℃ | ||
Enclosure | Protection level | IP20 | |
Cooling | Fan cooling | ||
Mounting mode | Mounted in a cabinet |
Inverter series
Inverter model(G:Constant; P:Pump, fan load) | Rated capacity(kVA) | Rated input current(A) | Rated output current(A) | Moto power(kW) |
---|---|---|---|---|
HV1000-2S0R4G | 1.0 | 5.3 | 2.5 | 0.4 |
HV1000-2S0R7G | 1.5 | 8.2 | 4.0 | 0.75 |
HV1000-2S1R5G | 3.0 | 14.0 | 7.5 | 1.5 |
HV1000-2S2R2G | 4.0 | 23.0 | 10.0 | 2.2 |
HV1000-4T-0R7G | 1.5 | 3.4 | 2.3 | 0.75 |
HV1000-4T-1R5G | 3.0 | 5.0 | 3.7 | 1.5 |
HV1000-4T-2R2G | 4.0 | 5.8 | 5.0 | 2.2 |
HV1000-4T-004G | 6.3 | 10.0 | 9.0 | 4 |
HV1000-4T-5R5G/7R5P | 8.5/11.0 | 15.5/20.5 | 13.0/17.0 | 5.5/7.5 |
HV1000-4T-7R5G/011P | 11.0/17.0 | 20.5/26.0 | 17.0/25.0 | 7.5/11 |
HV1000-4T-011G/015P | 17.0/21.0 | 26.0/35.0 | 25.0/32.0 | 11/15 |
HV1000-4T-015G/0185P | 21.0/24.0 | 35.0/38.5 | 32.0/37.0 | 15/18.5 |
HV1000-4T-0185G/022P | 24.0/30.0 | 38.5/46.5 | 37.0/45.0 | 18.5/22 |
HV1000-4T-022G/030P | 30.0/40.0 | 46.5/62.0 | 45.0/60.0 | 22/30 |
HV1000-4T-030G/037P | 40.0/50.0 | 62.0/76.0 | 60.0/75.0 | 30/37 |
HV1000-4T-037G/045P | 50.0/60.0 | 76.0/92.0 | 75.0/90.0 | 37/45 |
HV1000-4T-045G/055P | 60.0/72.0 | 92.0/113.0 | 90.0/110.0 | 45/55 |
HV1000-4T-055G/075P | 72.0/100.0 | 113.0/157.0 | 110.0/152.0 | 55/75 |
HV1000-4T-075G/090P | 100.0/116.0 | 157.0/180.0 | 152.0/176.0 | 75/90 |
HV1000-4T-090G/110P | 116.0/138.0 | 180.0/214.0 | 176.0/210.0 | 90/110 |
HV1000-4T-110G/132P | 138.0/167.0 | 214.0/256.0 | 210.0/253.0 | 110/132 |
HV1000-4T-132G/160P | 171.0/201.0 | 265.0/310.0 | 260.0/305.0 | 132/160 |
HV1000-4T-160G/185P | 201.0/250.0 | 310.0/385.0 | 305.0/380.0 | 160/185 |
HV1000-4T-200G/220P | 250.0/280.0 | 385.0/430.0 | 380.0/425.0 | 200/220 |
HV1000-4T-220G/250P | 280.0/316.0 | 430.0/485.0 | 425.0/480.0 | 220/250 |
HV1000-4T-250G/280P | 316.0/349.0 | 485.0/545.0 | 480.0/530.0 | 250/280 |
HV1000-4T-280G/315P | 349.0/395.0 | 545.0/610.0 | 530.0/600.0 | 280/315 |
HV1000-4T-315G/350P | 395.0/428.0 | 610.0/625.0 | 600.0/650.0 | 315/350 |
HV1000-4T-350G/400P | 428.0/474.0 | 625.0/715.0 | 650.0/720.0 | 350/400 |
HV1000-4T-400G/450P | 474.0/510.0 | 715.0/775.0 | 720.0/755.0 | 400/450 |
HV1000-4T-450G/500P | 510.0/586.0 | 775.0/890.0 | 755.0/860.0 | 450/500 |
HV1000-4T-500G/560P | 586.0/566.0 | 890.0/950.0 | 860.0/920.0 | 500/560 |
![]() |
Specialized frequency inverter /VSD/AC drive for injection machine Images |